Wednesday, February 13, 2013

List of thermal power stations in North India


Thermal Power
Thermal power is the largest source of power in India.There are different types of Thermal power plants based on the fuel used to generate the steam such as coalgasDiesel etc. About 75% of electricity consumed in India are generated by Thermal power plants.


NameOperatorLocationDistrictStateSectorRegionUnitsCapacity
(MW)
Coordinates
Rajghat Power StationIPGCLRajghatNorth DelhiDelhiStateNorthern2 X 67.5135.00
Panipat Thermal Power Station IHPGCLAssanPanipatHaryanaStateNorthern4 x 110440.0029°23′51″N76°52′32″E
Panipat Thermal Power Station IIHPGCLAssanPanipatHaryanaStateNorthern2 x 210, 2 x 250920.0029°23′51″N76°52′32″E
Faridabad Thermal Power StationHPGCLFaridabadFaridabadHaryanaStateNorthern1 x 5555.0028°22′28″N77°18′21″E
Rajiv Gandhi Thermal Power StationHPGCLKhedarHisarHaryanaStateNorthern1 x 600600.0029°21′25″N75°52′02″E
Guru Nanak dev TPPSPCLBathindaBathindaPunjabStateNorthern4 x 110440.0030°14′02″N74°55′26″E
Guru Hargobind TPPSPCLLehra MohabbatBathindaPunjabStateNorthern2 x 210, 2 x 250920.0030°16′04″N75°09′53″E
Guru Gobind Singh Super Thermal Power PlantPSPCLGhanauliRupnagarPunjabStateNorthern6 x 2101260.0031°02′32″N76°35′02″E
Suratgarh Super Thermal Power PlantRVUNLSuratgarhSri GanganagarRajasthanStateNorthern6 x 2501500.0029°10′56″N74°01′09″E
Kota Super Thermal Power PlantRVUNLKotaKotaRajasthanStateNorthern2 x 110, 3 x 210, 2 x 1951240.0025°10′17″N75°48′54″E
Giral Lignite Power PlantRVUNLThumbliBarmerRajasthanStateNorthern2 x 125250.0026°02′44″N71°15′13″E
Chhabra Thermal Power PlantRVUNLMothipuraBaranRajasthanStateNorthern2 x 250500.0024°37′14″N77°02′10″E
Obra Thermal Power StationUPRVUNLObraSonebhadraUttar PradeshStateNorthern1 x 40, 3 x 94, 5 x 2001,322.0024°26′41″N82°58′41″E
Anpara Thermal Power StationUPRVUNLAnparaSonebhadraUttar PradeshStateNorthern3 x 210, 2 x 5001630.0024°12′11″N82°47′18″E
Panki Thermal Power StationUPRVUNLPankiKanpurUttar PradeshStateNorthern2 x 105210.0026°28′35″N80°14′31″E
Parichha Thermal Power StationUPRVUNLParichhaJhansiUttar PradeshStateNorthern2 x 110, 2 x 210640.0025°30′51″N78°45′36″E
Harduaganj Thermal Power StationUPRVUNLHarduaganjAligarhUttar PradeshStateNorthern1 x 55, 1 x 60, 1 x 105220.0028°01′00″N78°07′50″E
Badarpur Thermal Power StationNTPCBadarpurNew DelhiNCT DelhiCentralNorthern3 x 95, 2 x 210705.0028°30′22″N77°18′26″E
Singrauli Super Thermal Power StationNTPCShaktinagarSonebhadraUttar PradeshCentralNorthern5 x 200, 2 x 500,2000.0024°06′16″N82°42′27″E
Barsingsar Lignite Power PlantNLCBarsingsarBikanerRajasthanCentralNorthern2 x 125250.0027°49′09″N73°12′28″E
Rihand Thermal Power StationNTPCRihand NagarSonebhadraUttar PradeshCentralNorthern4 x 5002000.0024°01′39″N82°47′28″E
NTPC DadriNTPCVidyutnagarGautam Budh NagarUttar PradeshCentralNorthern4 x 210, 2 x 4901820.0028°36′04″N77°36′25″E
Feroj Gandhi Unchahar Thermal Power PlantNTPCUnchaharRaebareliUttar PradeshCentralNorthern5 x 2101050.0025°54′52″N81°19′33″E
Tanda Thermal Power PlantNTPCVidyutnagarAmbedkar NagarUttar PradeshCentralNorthern4 x 110440.0026°35′22″N82°36′04″E
Raj west Lignite Power PlantJSWBarmerBarmerRajasthanPrivateNorthern8 x 135135.0025°53′20″N71°19′25″E
VS Lignite Power PlantKSKGurhaBikanerRajasthanPrivateNorthern1 x 125125.0027°51′18″N72°51′22″E
Rosa Thermal Power PlantRelianceRosaShahjahanpurUttar PradeshPrivateNorthern4 x 3001200.00[5]27°49′07″N79°56′10″E

Guru Nanak Dev Thermal Plant

1)
Location
Bathinda (Punjab)
2)
Main Features
Highest Generation achievement in 2007-08 (3008MU)
Highest PLF in March 1987 (88.14%)
Lowest Ever yearly aux. consumption 2002-03 (9.32% without T&E Losses)
Lowest DM Water make up in 2004-05 (2.02%)
Lowest Oil Consumption in 2002-03 (1.35ml/Kwh)
3)
No. of Power House
ONE
4)
No. of Unit
FOUR
5)
Total generating capacity
4 x 110 MW = 440 MW
6)
Source of water supply
Canal water
7)
Fuel Used
Primary Fuel: Bituminous coal with calorific value 3500-4500 kcal/kg
Secondary Fuel: Fuel oil/L.D.O./HPS/FO with calorific value of 9,000 to 10,000 K.Cal / liter.
8)
Turbine
Three casing type impulse turbines 110 MW capacity with 3000 rpm, 29 stages with exhaust pressure 0.08 kg/sq. cm
9)
Generator
BHEL make three phase synchronous type  110 MW,11000 V with H2 cooling and DC/Static exciter ( 2 units with Static Exciter & 2 units with separate DC exciter)
10)
Commissioning
U-1 = 22.9.74   U-2 = 19.9.75
U-3 = 29.3.78   U-4 = 31.1.79
Date of commissioning after R&M :
U-1 = 15.04.2007 U-1 = 19.01.2006
11)
Cost of Project
Original Cost: Rs. 115 Crores
R&M Cost for U#1 & U#2= Rs. 229 Crore
R&M Cost for U#3 & U#4= Rs. 465 Crore

GURU GOBIND SINGH SUPER THERMAL PLANT

1)LocationNear Village Ghanauli on Chandigarh/Ropar Nangal Road 12 km from Ropar 55 km from Chandigarh.
2)Main Features
  • Shield & excellent performance by Prime Minister of India during 1986-87 for achieving 78.08 % PLF against all India average of 53.2 %.
  • Incentive award for reducing fuel oil consumption during 1999.
  • Peak load hour generation award during 1999-2000.
3)No. of Power Houses6
4)No. of Units6
5)Total generating capacity6 x 210 MW = 1260 MW
6)Source of water supplyFrom Nangal Hydel Channel
7)Fuel usedCoal from coal fields of Bihar, West Bengal and Madhya Pradesh from more than 50 sources called collieries. Distance of these sources is between 1417 km and 1560 km.
8)Turbines210 MW 3 cylinder mixed flow tandem coupled 3000 rpm BHEL make.
9)Generators247 MVA, 15.75 kV, 9050 A at 0.85 lag, 50 Hz, 3 phase, double star two pole.
10)CommissioningU1 = 26.9.84  U2 = 29.3.85  U3 = 31.3.88
U4 = 29.1.89  U5 = 29.3.92  U6 = 30.3.93
11)Cost of Project
ST - IRs. 380 Crores
ST - IIRs. 438 Crores
ST - IIIRs. 599 Crores
12)Total energy contribution annually6942 MUs
13)Cost per unitRs. 1.84/-

Rankine cycle


Rankine cycle

The Rankine cycle is a mathematical model that is used to predict the performance of steam engines. The Rankine cycle is an idealised thermodynamic cycle of a heat engine that converts heat into mechanical work. The heat is supplied externally to a closed loop, which usually uses water as the working fluid. The Rankine cycle, in the form of steam engines generates about 90% of all electric power used throughout the world,[1] including virtually all solar thermalbiomasscoal and nuclear power plants. It is named after William John Macquorn Rankine, a Scottishpolymath and Glasgow University professor.

Description

Physical layout of the four main devices used in the Rankine cycle
The Rankine cycle most closely describes the process by which steam-operated heat engines most commonly found in power generation plants generate power. The two most common heating processes used in these power plants are nuclear fission and the combustion of fossil fuels such as coalnatural gas, and oil.
The Rankine cycle is sometimes referred to as a practical Carnot cycle because, when an efficient turbine is used, the TS diagram begins to resemble the Carnot cycle. The main difference is that heat addition (in the boiler) and rejection (in the condenser) are isobaric in the Rankine cycle andisothermal in the theoretical Carnot cycle. A pump is used to pressurize the working fluid received from the condenser as a liquid instead of as a gas. All of the energy in pumping the working fluid through the complete cycle is lost, as is most of the energy of vaporization of the working fluid in the boiler. The vaporization energy is rejected from the cycle through the condenser. But pumping the working fluid through the cycle as a liquid requires a very small fraction of the energy needed to transport it as compared to compressing the working fluid as a gas in a compressor (as in theCarnot cycle).
The efficiency of a Rankine cycle is usually limited by the working fluid. Without the pressure reaching super critical levels for the working fluid, the temperature range the cycle can operate over is quite small: turbine entry temperatures are typically 565°C (the creep limit of stainless steel) and condenser temperatures are around 30°C. This gives a theoretical Carnot efficiency of about 63% compared with an actual efficiency of 42% for a modern coal-fired power station. This low turbine entry temperature (compared with a gas turbine) is why the Rankine cycle is often used as a bottoming cycle in combined-cycle gas turbine power stations.
The working fluid in a Rankine cycle follows a closed loop and is reused constantly. The water vapor with entrained droplets often seen billowing from power stations is generated by the cooling systems (not from the closed-loop Rankine power cycle) and represents the waste heat energy (pumping and condensing) that could not be converted to useful work in the turbine. Note that cooling towers operate using the latent heat of vaporization of the cooling fluid. While many substances could be used in the Rankine cycle, water is usually the fluid of choice due to its favorable properties, such as nontoxic and nonreactive chemistry, abundance, and low cost, as well as its thermodynamic properties.
One of the principal advantages the Rankine cycle holds over others is that during the compression stage relatively little work is required to drive the pump, the working fluid being in its liquid phase at this point. By condensing the fluid, the work required by the pump consumes only 1% to 3% of the turbine power and contributes to a much higher efficiency for a real cycle. The benefit of this is lost somewhat due to the lower heat addition temperature. Gas turbines, for instance, have turbine entry temperatures approaching 1500°C. Nonetheless, the efficiencies of actual large steam cycles and large modern gas turbines are fairly well matched.

[edit]The four processes in the Rankine cycle

Ts diagram of a typical Rankine cycle operating between pressures of 0.06bar and 50bar
There are four processes in the Rankine cycle. These states are identified by numbers (in brown) in the above Ts diagram.
  • Process 1-2: The working fluid is pumped from low to high pressure. As the fluid is a liquid at this stage the pump requires little input energy.
  • Process 2-3: The high pressure liquid enters a boiler where it is heated at constant pressure by an external heat source to become a dry saturated vapor. The input energy required can be easily calculated using mollier diagram or h-s chart or enthalpy-entropy chart also known as steam tables.
  • Process 3-4: The dry saturated vapor expands through a turbine, generating power. This decreases the temperature and pressure of the vapor, and some condensation may occur. The output in this process can be easily calculated using the Enthalpy-entropy chart or the steam tables.
  • Process 4-1: The wet vapor then enters a condenser where it is condensed at a constant pressure to become a saturated liquid.
In an ideal Rankine cycle the pump and turbine would be isentropic, i.e., the pump and turbine would generate no entropy and hence maximize the net work output. Processes 1-2 and 3-4 would be represented by vertical lines on the T-S diagram and more closely resemble that of the Carnot cycle. The Rankine cycle shown here prevents the vapor ending up in the superheat region after the expansion in the turbine, [1] which reduces the energy removed by the condensers.


Thevenin's theorem


Thevenin's theorem

Thévenin's theorem holds, to illustrate in DC circuit theory terms,
  • Any linear electrical network with voltage and current sources and resistances can be replaced at terminals A-B by an equivalent voltage source Vth inseries connection with an equivalent resistance Rth.
  • This equivalent voltage Vth is the voltage obtained at terminals A-B of the network with terminals A-B open circuited.
  • This equivalent resistance Rth is the resistance obtained at terminals A-B of the network with all its current sources open circuited and all its voltage sources short circuited.